我还没有完全配置SCM导出插件并保存设置,我认为一旦将ssh密钥添加到Rundeck存储中,我就会继续配置。不幸的是,当转到JOBS或SETUP SCM...页面时,Rundeck现在将超时。我尝试使用API,但在尝试获取SCM插件详细信息时也会超时。
有没有包含SCM导出配置的文件或表,我可以手动删除并重新配置?
错误消息:
[2021-08-01T01:00:00,000] ERROR services.ScmService - Unable to initialize SCM for project myproject for integration export
com.dtolabs.rundeck.plugins.scm.ScmPluginException: Failed fetch from the repository: git@domain:path/rundeck.git: Connection timed out (Connection timed out); java.net.ConnectException: Connection timed out (Connection timed out)
at jdk.internal.reflect.GeneratedConstructorAccessor319.newInstance(Unknown Source) ~[?:?]
...发布于 2021-08-13 07:00:29
我在Rundeck数据库里找到了配置。删除行后,我可以再次访问SCM配置。
mysql> select name from storage limit 10;
+--------------------------+
| name |
+--------------------------+
| workflowConfigFix973 |
| project.properties |
| project.properties |
| user.aclpolicy.aclpolicy |
| scm-export.properties |
+--------------------------+
5 rows in set (0.00 sec)
mysql> delete from storage where name = 'scm-export.properties';
Query OK, 1 row affected (0.01 sec)https://stackoverflow.com/questions/68767384