Sigfox_CLI_Demo_Project允许连续波模式传输以进行测试,并且命令表中有一个命令行界面命令start_continuous_transmission。但是,我不知道如何输入频率。
我尝试将920.8 get的频率设置为920800000,但得到错误0x0058。我也尝试了"RC4“,但也得到了相同的错误代码。
{ "start_continuous_transmission",SIGFOX_API_start_continuous_transmission_Action, "wu", ""}, \
void SIGFOX_API_start_continuous_transmission_Action(void)
{
sfx_u32 frequency=(uint32_t)920800000;//(uint32_t)unsignedCommandArgument(0);
sfx_modulation_type_t mode=(sfx_modulation_type_t)0;//unsignedCommandArgument(1);
sfx_error_t err;
err=SIGFOX_API_start_continuous_transmission(frequency, mode);
responsePrintf("{&N API call...&tx}\r\n",
"SIGFOX_API_start_continuous_transmission", "sfx_error", err);
}我得到一个错误0x0058。
请帮帮忙。谢谢!
发布于 2020-03-06 10:23:32
首先关闭sigfox库,例如node_close
https://stackoverflow.com/questions/57847414
复制相似问题