回答 2查看 591关注 0票数 3

今天早些时候,我收到了一封来自mdadm监视器的自动电子邮件,内容如下:

代码语言:javascript
复制
This is an automatically generated mail message from mdadm
running on server

This is an automatically generated mail message from mdadm
running on server

A Fail event had been detected on md device /dev/md127.

It could be related to component device /dev/sdd1.

Faithfully yours, etc.

P.S. The /proc/mdstat file currently contains the following:

Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] 
md127 : active raid10 sda1[0] sdc1[2] sdd1[3](F) sdb1[1]
  5860267008 blocks super 1.2 512K chunks 2 near-copies [4/3] [UUU_]
  [==========>..........]  check = 50.9% (2983082496/5860267008) finish=1025.1min speed=46774K/sec

unused devices: <none>

我刚刚登录到服务器并运行了cat /proc/mdstat,结果是:

代码语言:javascript
复制
Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] 
md127 : active raid10 sda1[0] sdb1[1] sdc1[2]
      5860267008 blocks super 1.2 512K chunks 2 near-copies [4/3] [UUU_]

unused devices: <none>

我理解得对吗?驱动器坏了吗?

EN

回答 2

Server Fault用户

回答已采纳

发布于 2017-09-06 08:04:26

您有512 E磁盘sdd。这意味着旧的BIOS、旧的SATA控制器或旧的OS驱动程序可能有一些未知的问题。此磁盘的智能数据显示其健康状况良好。sdd磁盘很好!

为什么它被标记为失败?我认为有很多原因:

  1. 权力更少。只需安装新的更高的电源单元。这个磁盘在高负载时可以消耗高达20W的功率。
  2. 禁用服务器电源管理。也为你的磁盘做它。或者设置最大性能。禁用OS电源服务,如powerdcpuspeed等。
  3. 老的SATA控制器在高负载时会出现误动。尝试更新BIOS。如果这对您没有帮助,那么安装新的SATA控制器(它适当地支持4K512E磁盘)或将主板更改为新的。

另一种方法--只使用512n旧模型磁盘。它们的容量可达4Tb。

票数 1
EN

Server Fault用户

发布于 2017-09-03 20:23:20

是的,sdd1失败了。

从原来的电子邮件

md127 : active raid10 sda10 sdc12 sdd13. sdb11 5860267008块超级1.212K块2近拷贝4/3

从你的观察来看

md127 : active raid10 sda10 sdb11 sdc12 5860267008块超级1.212K块2近拷贝4/3

理想情况下,数组应该有4个设备,但它只有3个。

票数 3