回答 3查看 5.2K关注 0票数 3

我正在尝试让两个运行MariaDB 10.1.764位的服务器之间的复制工作。我试图复制的数据库是巨大的,520 G和导出/导入禁用的自动提交的奴隶花了5天。当我最初开始复制时,奴隶似乎要赶上了。实际上看上去很有希望。可悲的是,30分钟后,当我再次检查奴隶时,我意识到它实际上已经落后了。一周后的晚上,当主人不那么忙的时候,它真的看起来又赶上了,但是不幸的是,现在Seconds_Behind_Master已经快一周了。我将slave_parallel_mode设置为主动,而在从服务器上,slave_parallel_threads设置为30,而在主服务器上,设置为10。innodb_flush_log_at_trx_commit变量在从服务器上为1,在主服务器上为0。以下是主服务器的配置:

代码语言:javascript
复制
[client]
port          = 3306
socket        = /var/lib/mysql/mysqld.sock
[mysqld]
port          = 3306
socket        = /var/lib/mysql/mysqld.sock
log-error=/var/log/mysql/logs/mysql.log
datadir=/RAID50/innodb/mysql/
init-connect = 'SET NAMES UTF8'
character-set-server = utf8
server_id=1
sync_binlog=1
back_log = 50
max_connections = 450
max_connect_errors = 9999999
table_cache = 4096
max_allowed_packet = 16M
binlog_cache_size = 1M
max_binlog_size = 100M
max_heap_table_size = 64M
sort_buffer_size = 8M
join_buffer_size = 8M
thread_cache_size = 16
query_cache_size = 128M
query_cache_limit = 4M
query_alloc_block_size = 16K
expire_logs_days=14
# Set the default table type

event_scheduler=ON
default-storage-engine=InnoDB 
thread_stack = 192K
transaction_isolation = READ-COMMITTED
tmp_table_size = 64M
log-bin=/binlog/mysql/master-bin
# binary logging format - mixed recommended
binlog_format=mixed

slow_query_log_file=/var/log/mysql/logs/slow-queries.log
slow_query_log=1
long_query_time=1
tmpdir = /tmp 
slave_load_tmpdir = /var/log/mysql/tmpfs
innodb_additional_mem_pool_size = 32M

# This config file assumes a main memory of at least 8G
# innodb_buffer_pool_size = 6.5G    # Default setting
innodb_buffer_pool_size = 8G

# Set this option if you would like the InnoDB tablespace files to be
# stored in another location. By default this is the MySQL datadir.
innodb_file_per_table = 1
innodb_data_home_dir = /RAID50/innodb/mysql/
innodb_file_format = Barracuda
innodb_data_file_path = ibdata1:156M;ibdata2:156M:autoextend
# innodb_data_file_path = /data1/innodb/mysql/
innodb_autoextend_increment=156M


# Number of threads allowed inside the InnoDB kernel. The optimal value
# depends highly on the application, hardware as well as the OS
# scheduler properties. A too high value may lead to thread thrashing.
# innodb_thread_concurrency = 16
innodb_thread_concurrency = 32

innodb_flush_log_at_trx_commit = 0
innodb_log_buffer_size = 8M

# make sure the log files are large enough that you don't hold up
# checkpoints when the logs rotate!
innodb_log_file_size = 200M

# Total number of files in the log group. A value of 2-3 is usually good
# enough.
innodb_log_files_in_group = 2
innodb_log_group_home_dir = /var/log/mysql/innodb_logs
innodb_max_dirty_pages_pct = 80
# use directIO to bypass filesystem cache where possible
innodb_flush_method=O_DIRECT
innodb_lock_wait_timeout = 30
innodb_commit_concurrency=0
innodb_open_files=2000
[mysqldump]
# Do not buffer the whole result set in memory before writing it to
# file. Required for dumping very large tables
quick
max_allowed_packet = 16M

[mysql]
no-auto-rehash

default-character-set = utf8

# Only allow UPDATEs and DELETEs that use keys.
#safe-updates

[isamchk]
key_buffer = 512M
sort_buffer_size = 512M
read_buffer = 8M
write_buffer = 8M
[myisamchk]
key_buffer = 512M
sort_buffer_size = 512M
read_buffer = 8M
write_buffer = 8M
[mysqlhotcopy]
interactive-timeout
[mysqld_safe]
# Increase the amount of open files allowed per process. Warning: Make
# sure you have set the global system limit high enough! The high value
# is required for a large number of opened tables
open-files-limit = 102400

这是从服务器的配置文件:

代码语言:javascript
复制
[mysqld]
datadir=/data1/mysql
socket=/var/lib/mysql/mysql.sock
# replication implementation
server-id=101
log-bin=mysql-bin
binlog_format=mixed
read-only=1
relay-log=mysql-relay-bin
log-slave-updates=1
# Disabling symbolic-links is recommended to prevent assorted security risks
symbolic-links=0
# Settings user and group are ignored when systemd is used.
# If you need to run mysqld under a different user or group,
# customize your systemd unit file for mariadb according to the
# instructions in http://fedoraproject.org/wiki/Systemd

init-connect = 'SET NAMES UTF8'
character-set-server = utf8
innodb_file_per_table = 1
innodb_file_format = Barracuda
innodb_data_file_path = ibdata1:156M;ibdata2:156M:autoextend
innodb_thread_concurrency = 32
innodb_flush_log_at_trx_commit = 0
innodb_log_buffer_size = 8M
innodb_log_file_size = 200M
innodb_log_files_in_group = 2
innodb_max_dirty_pages_pct = 80
innodb_flush_method=O_DIRECT
innodb_lock_wait_timeout = 30
innodb_commit_concurrency=0
innodb_open_files=2000
slave_parallel_threads = 10

[mysqld_safe]
log-error=/var/log/mysqld.log
pid-file=/var/run/mysqld/mysqld.pid
open-files-limit = 102400

#
# include all files from the config directory
#
#!includedir /etc/my.cnf.d

以下是显示从状态的输出\G:

代码语言:javascript
复制
MariaDB [(none)]> SHOW SLAVE STATUS \G
*************************** 1. row ***************************
               Slave_IO_State: Waiting for master to send event
                  Master_Host: 192.168.11.25
                  Master_User: replicant
                  Master_Port: 3306
                Connect_Retry: 60
              Master_Log_File: master-bin.005174
          Read_Master_Log_Pos: 86423579
               Relay_Log_File: mysql-relay-bin.000109
                Relay_Log_Pos: 77202510
        Relay_Master_Log_File: master-bin.005116
             Slave_IO_Running: Yes
            Slave_SQL_Running: Yes
              Replicate_Do_DB: 
          Replicate_Ignore_DB: 
           Replicate_Do_Table: 
       Replicate_Ignore_Table: 
      Replicate_Wild_Do_Table: 
  Replicate_Wild_Ignore_Table: 
                   Last_Errno: 1932
                   Last_Error: Unable to load replication GTID slave state from mysql.gtid_slave_pos: Table 'mysql.gtid_slave_pos' doesn't exist in engine
                 Skip_Counter: 0
          Exec_Master_Log_Pos: 77202221
              Relay_Log_Space: 6273918609
              Until_Condition: None
               Until_Log_File: 
                Until_Log_Pos: 0
           Master_SSL_Allowed: No
           Master_SSL_CA_File: 
           Master_SSL_CA_Path: 
              Master_SSL_Cert: 
            Master_SSL_Cipher: 
               Master_SSL_Key: 
        Seconds_Behind_Master: 580994
Master_SSL_Verify_Server_Cert: No
                Last_IO_Errno: 0
                Last_IO_Error: 
               Last_SQL_Errno: 1932
               Last_SQL_Error: Unable to load replication GTID slave state from mysql.gtid_slave_pos: Table 'mysql.gtid_slave_pos' doesn't exist in engine
  Replicate_Ignore_Server_Ids: 
             Master_Server_Id: 1
               Master_SSL_Crl: 
           Master_SSL_Crlpath: 
                   Using_Gtid: No
                  Gtid_IO_Pos: 
      Replicate_Do_Domain_Ids: 
  Replicate_Ignore_Domain_Ids: 
                Parallel_Mode: aggressive
1 row in set (0.00 sec)

我确实知道无法从mysql.gtid_slave_pos加载复制GTID从状态:在引擎中不存在表'mysql.gtid_slave_pos‘,应该修复它,但我不确定它是否是复制滞后的原因。有人知道我该怎么调整吗?从机拥有比主程序更好的CPU。

EN

回答 3

Server Fault用户

发布于 2015-11-26 15:59:11

说"mysql.gtid_slave_pos不存在“的错误正在阻止从服务器上的复制过程。在继续复制之前,需要修复此错误。

您可以尝试忽略此错误并查看发生了什么。在从服务器上连接mysql,并键入以下内容:

代码语言:javascript
复制
mysql> STOP SLAVE;
mysql> SET GLOBAL SQL_SLAVE_SKIP_COUNTER = 1;
mysql> START SLAVE;
票数 2
EN

Server Fault用户

发布于 2017-04-07 05:09:14

您可以尝试如下所示的步骤

运行mysql升级。

mysql_upgrade -u root -p

如果它的显示错误如

错误:指定为定义者的用户('appuser'@'%')不存在错误:损坏的阶段3/6:在第64行运行'mysql_fix_privilege_tables‘错误1813 (HY000):表'mysql.innodb_table_stats’的表空间存在。请在导入前丢弃表空间。错误1813 (HY000)在第68行:表'mysql.innodb_index_stats‘的表空间存在。请在导入前丢弃表空间。错误1813 (HY000)在第136行:表'mysql.gtid_slave_pos‘的表空间存在。请在导入前丢弃表空间。错误1146 (42S02)在第581行:表'mysql.innodb_index_stats‘不存在错误1146 (42S02)在第584行:表'mysql.innodb_table_stats’不存在致命错误:升级失败

而不是在备份所有文件\文件夹后从mysql/mysql文件夹中删除所有.ibd文件。

rm gtid_slave_pos.ibd rm innodb_index_stats.ibd innodb_table_stats.ibd

现在再次运行mysql_upgrade -u root -p。

并升级所有数据库并自动创建所需的所有文件。

票数 -1
EN

Server Fault用户

发布于 2017-05-30 07:31:07

您只需重新创建该表就可以修复此问题。

http://alidba.blogspot.in/2017/05/table-mysqlgtidslavepos-doesnt-exist.html