我有几个开关,是在同一机架上,必须通过光纤OM2,50/125 MM,LC/LC (两个额外的例子,参考是10 the和是OM3)。
威瑞森的一位技术人员告诉我,他必须增加衰减器,因为激光太强,会烧毁光学系统。
我从来没有听说过,在这些数据库级别上有什么最佳实践吗?
Juniper的输出
>show interfaces diagnostics optics ge-0/2/1
Physical interface: ge-0/2/1
Laser bias current : 5.284 mA
Laser output power : 0.3120 mW / -5.06 dBm
Module temperature : 35 degrees C / 95 degrees F
Module voltage : 3.2670 V
Receiver signal average optical power : 0.2986 mW / -5.25 dBm
Laser bias current high alarm threshold : 13.000 mA
Laser bias current low alarm threshold : 1.000 mA
Laser bias current high warning threshold : 12.500 mA
Laser bias current low warning threshold : 2.000 mA
Laser output power high alarm threshold : 1.0000 mW / 0.00 dBm
Laser output power low alarm threshold : 0.0440 mW / -13.57 dBm
Laser output power high warning threshold : 0.5010 mW / -3.00 dBm
Laser output power low warning threshold : 0.1120 mW / -9.51 dBm
Module temperature high alarm threshold : 110 degrees C / 230 degrees F
Module temperature low alarm threshold : -40 degrees C / -40 degrees F
Module temperature high warning threshold : 93 degrees C / 199 degrees F
Module temperature low warning threshold : -30 degrees C / -22 degrees F
Module voltage high alarm threshold : 3.600 V
Module voltage low alarm threshold : 3.000 V
Module voltage high warning threshold : 3.500 V
Module voltage low warning threshold : 3.100 V
Laser rx power high alarm threshold : 1.1220 mW / 0.50 dBm
Laser rx power low alarm threshold : 0.0079 mW / -21.02 dBm
Laser rx power high warning threshold : 0.7943 mW / -1.00 dBm
Laser rx power low warning threshold : 0.0200 mW / -16.99 dBm我的核心开关的输出
CoreSwitch#sh interfaces tengigabitethernet 0/46
TenGigabitEthernet 0/46 is up, line protocol is up
Port is part of Port-channel 127
Description: Juniper
Hardware is DellEth, address is 00:00:00:00:00:00
Current address is 00:00:00:00:00:00
Pluggable media present, SFP type is 1000BASE-SX
Wavelength is 850nm
SFP receive power reading is -5.8704dBm
CoreSwitch#sh int te0/7
TenGigabitEthernet 0/7 is up, line protocol is up
Port is part of Port-channel 7
Description: Access Switch Stack 1
Hardware is DellEth, address is 00:00:00:00:00:00
Current address is 00:00:00:00:00:00
Pluggable media present, SFP+ type is 10GBASE-SR
Medium is MultiRate, Wavelength is 850nm
SFP+ receive power reading is -8.9177dBm
CoreSwitch#show int te0/6
TenGigabitEthernet 0/6 is up, line protocol is up
Port is part of Port-channel 6
Description: Access Switch Stack 2
Hardware is DellEth, address is 00:00:00:00:00:00
Current address is 00:00:00:00:00:00
Non-qualified pluggable media present, SFP+ type is 10GBASE-SR
Medium rate is unknown, Wavelength is 850nm
SFP+ receive power reading is -3.0356dBm-5 dBm可接受吗?默认的‘警报器’在-1到-16之间,但我应该瞄准-10 dBm,把钱花在5分贝衰减器上吗?
发布于 2015-10-23 14:03:05
我在网络工程集团的一个链接上找到了答案,
功率过大的变送器造成的损害?

源页77-78来自你一直想知道的关于光网络的一切--但不敢问
由于短链路有效衰减0dB,在问题的上下文中,解释上述图表的方法是TX功率(显示为dBm值的范围)不应包括接收机盲值或接收机损坏阈值。我们可以看到,这个条件只满足于LR,而不是ER或ZR。因此,对于短链路(例如机架间,如在问题中,或实际上小于几公里的任何东西),ER (盲阈值)和ZR (失明和损坏阈值)可能需要衰减器,而LR设备则不需要衰减器。
发布于 2015-10-23 13:25:06
这取决于您正在使用的光纤模块。使用与您的运行长度相匹配的模块,您就会没事的。在机架上运行时,SX或SR模块在没有衰减器的情况下会很好.如果您使用长距离模块(LH、LX、EX、ZX、LR、LRM等),那么您可能会出现问题。每个模块将有一个最小的输出,这可能是高于安全地板(见您的模块的规格的最大接收功率,这通常是-1或更高)。
我从没见过在多模式电缆上使用衰减器。对于以单模提供光纤互联网的ISP来说,它们似乎相当普遍,在这种模式下,用户与ISP的前端相当接近。这可能是Verizon技术公司认为你需要在机架上使用它们的原因,而不是理解单模和多模电缆以及短程/长程光纤模块之间的区别。
发布于 2017-08-21 23:46:50
雅各布·埃文斯在这里有一个很好的答案。不过,我要澄清的一点是,LR上的发射机与ER或ZR完全不同。
多模收发器通常使用Vcsel或类似于它的光源,这些是无害的接收器,永远不会烧毁他们。
LR使用DFB或FB激光器,它们不是很强,也不会对接收器造成永久性伤害。
现在ER和ZRs使用EML或类似的激光(我们使用EML ),它们足够强大,在没有衰减器的情况下,在近距离内造成永久性伤害和过热。
我们已经得到回报,因为人们使用ER或ZR光学的方式太接近一个范围没有衰减器。这是我传递给人们的一条很好的经验法则。请注意,这些纯粹是为了硬件的安全。您可能需要根据网络设置进行调整。
10公里光学-不需要衰减
40 at光-4db衰减器在20公里,-8db在10公里
80 at光-10 at衰减器在40公里,15分贝在20公里,不推荐远低于20公里的距离。
https://serverfault.com/questions/731068
复制相似问题