我有一个戴尔PowerEdge 2950运行Solaris 10与8个驱动器。我想把一些硬盘换成新的。我现在的问题是,我只看到其中的一半,而且似乎没有其他4的迹象。
# cat /etc/release
Solaris 10 5/09 s10x_u7wos_08 X86
Copyright 2009 Sun Microsystems, Inc. All Rights Reserved.
Use is subject to license terms.
Assembled 30 March 2009# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c0::dsk/c0t2d0 disk connected configured unknown
c0::dsk/c0t3d0 disk connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb1/1 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
usb2/1 unknown empty unconfigured ok
usb2/2 unknown empty unconfigured ok
usb3/1 unknown empty unconfigured ok
usb3/2 unknown empty unconfigured ok
usb4/1 unknown empty unconfigured ok
usb4/2 unknown empty unconfigured ok
usb4/3 unknown empty unconfigured ok
usb4/4 unknown empty unconfigured ok
usb4/5 usb-hub connected configured ok
usb4/5.1 unknown empty unconfigured ok
usb4/5.2 unknown empty unconfigured ok
usb4/5.3 unknown empty unconfigured ok
usb4/5.4 unknown empty unconfigured ok
usb4/6 unknown empty unconfigured ok
usb4/7 unknown empty unconfigured ok
usb4/8 unknown empty unconfigured okraidctl绝对没有输出
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <DEFAULT cyl 8841 alt 2 hd 255 sec 63>
/pci@0,0/pci8086,25e3@3/pci8086,370@0/pci1028,1f03@e/sd@0,0
1. c0t1d0 <DELL-PERC 5/i-1.03-67.75GB>
/pci@0,0/pci8086,25e3@3/pci8086,370@0/pci1028,1f03@e/sd@1,0
2. c0t2d0 <DELL-PERC 5/i-1.03-67.75GB>
/pci@0,0/pci8086,25e3@3/pci8086,370@0/pci1028,1f03@e/sd@2,0
3. c0t3d0 <DELL-PERC 5/i-1.03-67.75GB>
/pci@0,0/pci8086,25e3@3/pci8086,370@0/pci1028,1f03@e/sd@3,0
Specify disk (enter its number): ^C发布于 2014-12-30 03:39:00
您需要从使用MegaCLI或MegaRAID存储管理器(正如)管理RAID控制器开始,这需要适当的驱动程序。Oracle的硬件比较列表为您指明了正确使用驱动程序的方向.
...but链接不好,很可能是因为硬件有多老。然而,快速搜索LSI站点仍然可以找到所需的驱动程序和软件:
驱动程序安装可能会解决这个问题.如果不是,您将不得不使用MegaCLI挖掘信息来排除故障。而不仅仅是留给您"RTFM",您还需要阅读一下MegaCLI指南,以找到如何获取相关数据的问题。你可以从一些网络搜索开始。"MegaCLI显示所有磁盘“),如果指南有点压倒性。
通过评论更新/是否有进展/结果?
https://serverfault.com/questions/655323
复制相似问题