我正在使用一个思科6500系列与单点登录冗余配置。显示冗余输出如下:
Hardware Mode = Duplex
Configured Redundancy Mode = sso
Operating Redundancy Mode = rpr
Maintenance Mode = Disabled
Communications = Up我假设设备在RPR模式下工作,尽管配置了SSO。是什么导致的?操作模式不应该是单点登录吗?
编辑(显示冗余状态):
my state = 13 -ACTIVE
peer state = 4 -STANDBY COLD
Mode = Duplex
Unit = Primary
Unit ID = 5
Redundancy Mode (Operational) = rpr
Redundancy Mode (Configured) = sso
Redundancy State = rpr
Split Mode = Disabled
Manual Swact = Enabled
Communications = Up
client count = 60
client_notification_TMR = 30000 milliseconds
keep_alive TMR = 9000 milliseconds
keep_alive count = 1
keep_alive threshold = 18
RF debug mask = 0x0发布于 2012-11-30 22:14:52
运行以下命令
show redundancy config-sync failures prc
show redundancy config-sync failures prc
show redundancy config-sync failures prc以及验证活动和备用代码是否运行相同版本的代码(此信息应该显示冗余。