假设我知道我想要的驱动器在Adapter 8,Virtual 0上,有没有办法获得Linux设备的名称(例如/dev/sdt)?我上的是RHEL 6.2。
-pdlist为每个物理驱动器显示一个WWN值,但这并没有多大帮助。-ldinfo不打印万维网或任何其他标识值。
# ./MegaCli64 -pdlist -a8 | grep WWN
WWN: 500051610003776C
WWN: 5000516100037BFC
WWN: 5000516100038090
WWN: 50005161000284F4
WWN: 5000516100037C0C
WWN: 5000516100037C5C
WWN: 50005161000310C8
WWN: 5000516100037F4C
# ls -1dt /dev/disk/by-id/wwn*
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd142c12c84d
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd142c0973e6
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd132c002573
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd122bf6e2f6
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd122beda52a
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd112be46f10
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd112bdb3ffb
/dev/disk/by-id/wwn-0x600605b0043e52d01721fd102bd20f14
# ./MegaCli64 -v
MegaCLI SAS RAID Management Tool Ver 8.03.08 Mar 15, 2012发布于 2012-04-19 15:57:05
您应该能够比较来自-pdlist的磁盘序列号和来自lshw的输出。
# MegaCLI -pdlist -a0 | grep "Inquiry Data:"
Inquiry Data: XXXXXXXXXXXXHitachi YYYYYYYY ZZZZZZ
...然后在lshw的输出中搜索序列号。设备名称将在logical name字段中。
我无法验证这一点,因为我的所有磁盘都在一个卷中。
将来自Target Id的MegaCLI与设备的scsi总线目标进行比较。在lshw中,它是bus info。
# MegaCli -ldinfo -Lall -aall
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 7.275 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 6
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Access Policy : Read/Write
Disk Cache Policy : Disabled
Ongoing Progresses:
Check Consistency : Completed 17%, Taken 89 min.
Encryption Type : None
Virtual Drive: 1 (Target Id: 1)
Name :
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 7.275 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 6
Span Depth : 1
Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
Access Policy : Read/Write
Disk Cache Policy : Disabled
Ongoing Progresses:
Check Consistency : Completed 17%, Taken 89 min.
Encryption Type : None来自lshw:
# lshw -class disk
...
*-enclosure UNCLAIMED
description: SCSI Enclosure
product: Bobcat
vendor: LSI CORP
physical id: 1.75.0
bus info: scsi@0:1.117.0
version: 0504
configuration: ansiversion=5
*-disk:0
description: SCSI Disk
product: MR9260-16i
vendor: LSI
physical id: 2.0.0
bus info: scsi@0:2.0.0
logical name: /dev/sda
version: 2.12
serial: svDASJ-f8kM-4qp5-BswW-3IKC-DDyA-djz8N7
size: 7450GiB
capacity: 7450GiB
capabilities: lvm2
configuration: ansiversion=5
*-disk:1
description: SCSI Disk
product: MR9260-16i
vendor: LSI
physical id: 2.1.0
bus info: scsi@0:2.1.0
logical name: /dev/sdb
version: 2.12
serial: NHUvUy-1tm4-aGYW-g6DZ-t1Z9-gxW8-JhvFfL
size: 7450GiB
capacity: 7450GiB
capabilities: lvm2
configuration: ansiversion=5发布于 2015-04-17 03:06:00
我只是在我的megaclisas状态叉中添加了一些支持,以便将逻辑驱动器与OS本机设备相匹配。下面是一个输出示例:
$ sudo ./megaclisas-status
-- Controller information --
-- ID | H/W Model | RAM | Temp | Firmware
c0 | LSI MegaRAID SAS 9271-8i | 1024MB | 88C | FW: 23.32.0-0009
c1 | LSI MegaRAID SAS 9280-4i4e | 512MB | N/A | FW: 12.15.0-0205
-- Array information --
-- ID | Type | Size | Strpsz | Flags | DskCache | Status | OS Path | InProgress
c0u0 | RAID-1 | 1817G | 256 KB | ADRA,WT | Enabled | Optimal | /dev/sda | None
c0u1 | RAID-5 | 16370G | 512 KB | ADRA,WB | Enabled | Optimal | /dev/sdb | None
c1u0 | RAID-0 | 476G | 256 KB | ADRA,WT | Enabled | Optimal | /dev/sdc | None
-- Disk information --
-- ID | Type | Drive Model | Size | Status | Speed | Temp | Slot ID | LSI Device ID
c0u0p0 | HDD | WD-WMC300422505WDC WD20EFRX-68AX9N0 80.00A80 | 1.817 TB | Online, Spun Up | 6.0Gb/s | 31C | [252:4] | 17
c0u0p1 | HDD | WD-WMC300421817WDC WD20EFRX-68AX9N0 80.00A80 | 1.817 TB | Online, Spun Up | 6.0Gb/s | 31C | [252:5] | 18
c0u1p0 | HDD | WD-WX41DA40LCE5WDC WD60EFRX-68MYMN1 82.00A82 | 5.456 TB | Online, Spun Up | 6.0Gb/s | 32C | [252:0] | 15
c0u1p1 | HDD | WD-WX41DA40L42RWDC WD60EFRX-68MYMN1 82.00A82 | 5.456 TB | Online, Spun Up | 6.0Gb/s | 31C | [252:1] | 12
c0u1p2 | HDD | WD-WX61DA4HAKFZWDC WD60EFRX-68MYMN1 82.00A82 | 5.456 TB | Online, Spun Up | 6.0Gb/s | 32C | [252:6] | 14
c0u1p3 | HDD | WD-WX41DA40LEF1WDC WD60EFRX-68MYMN1 82.00A82 | 5.456 TB | Online, Spun Up | 6.0Gb/s | 31C | [252:7] | 16
c1u0p0 | SSD | 0000000011310344CFE3M4-CT512M4SSD2 070H | 476.4 Gb | Online, Spun Up | 6.0Gb/s | N/A | [252:1] | 11
-- Unconfigured Disk information --该工具本身可在:http://step.polymtl.ca/~coyote/dist/megaclisas-status/megaclisas-status上使用
我希望这能帮到你,
文森
发布于 2014-01-15 01:10:23
最近,我已经在许多新服务器上解决了这个问题,我已经想出了一个解决方案!我们不使用RAID上的"RAID“卡,只是使用SAS驱动器作为JBOD。/dev/disk/by-id映射由SAS Address中的一个(或几个)关闭。这听起来很奇怪,但它能在我测试过的几十台服务器上工作。我还收到了独立确认,这对其他人是有效的。
千兆是一个简短的Perl脚本,它实现了上述发现。它生成一个从Linux驱动器sd*到MegaRaid驱动器ID的映射,并显示来自MegaRaid的万维网。在生产中使用了一段时间之后,我还添加了megablink和megaunblink来控制闪烁的LED。这个特性使我免于从服务器中拔出错误的驱动器。请在github上提交错误报告。

[图片感谢斯科特·弗勒姆 ]
https://serverfault.com/questions/381177