我在Ubuntu18.04上有硬盘问题,系统会随机地将我的根分区(/dev/sda4 4)重装为只读,原因是错误。
dmesg|grep 'I/O error'揭示了sda4的明显问题。我现在还没有确切的输出,因为这个盒子已经成功地重新启动了,而且目前还没有问题。
我的计划是运行一个文件系统检查文件系统。我仔细地跟踪了这个答案和本教程。在后一篇教程中,我使用了题为“如何在使用systemd时在Linux上重新启动系统后强制fsck检查文件系统”一节。
但是,在重新启动后,该命令的输出将不检查文件系统:
tune2fs -l /dev/sda4 | grep checked
Last checked: Sat Nov 21 15:36:56 2020我尝试过GRUB的这些变体,但它们都没有成功:
GRUB_CMDLINE_LINUX_DEFAULT="maybe-ubiquity fsck.mode=force"和
GRUB_CMDLINE_LINUX_DEFAULT="maybe-ubiquity fsck.mode=force fsck.repair=yes"是的,我确实经营过update-grub。我遗漏了什么?
smartctl -a /dev/sda的输出:
Device Model: Samsung SSD 860 EVO 250GB
Serial Number: S59WNG0MA22770K
LU WWN Device Id: 5 002538 e70265a2a
Firmware Version: RVT03B6Q
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: Unknown(0x09fc), ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed May 3 11:35:14 2023 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 85) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0033 038 038 010 Pre-fail Always - 311
9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 21420
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 14
177 Wear_Leveling_Count 0x0013 001 001 000 Pre-fail Always - 2041
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
183 Runtime_Bad_Block 0x0013 038 038 010 Pre-fail Always - 311
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0032 067 065 000 Old_age Always - 33
195 Hardware_ECC_Recovered 0x001a 200 200 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
235 Unknown_Attribute 0x0012 099 099 000 Old_age Always - 10
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 166281511800
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
256 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.<#>更新:
服务器今早再次崩溃(还在运行,但/被挂载为只读),下面是我在dmesg中看到的内容:
dmesg |grep sda
[70547.166349] sd 0:0:0:0: [sda] tag#13 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[70547.166354] sd 0:0:0:0: [sda] tag#13 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[70948.441912] sd 0:0:0:0: [sda] tag#15 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[70948.441918] sd 0:0:0:0: [sda] tag#15 CDB: Read(10) 28 00 1a cb 1c 00 00 00 08 00
[70948.441922] print_req_error: I/O error, dev sda, sector 449518592
[70948.442312] sd 0:0:0:0: [sda] tag#16 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[70948.442315] sd 0:0:0:0: [sda] tag#16 CDB: Read(10) 28 00 1a cb 1c 00 00 00 08 00
[70948.442316] print_req_error: I/O error, dev sda, sector 449518592
[70948.442955] sd 0:0:0:0: [sda] tag#17 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[70948.442960] sd 0:0:0:0: [sda] tag#17 CDB: Read(10) 28 00 0e 0b 03 08 00 00 20 00
[70948.442962] print_req_error: I/O error, dev sda, sector 235602696
[70948.443389] sd 0:0:0:0: [sda] tag#18 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[70948.443393] sd 0:0:0:0: [sda] tag#18 CDB: Read(10) 28 00 0e 0b 03 08 00 00 08 00
[70948.443396] print_req_error: I/O error, dev sda, sector 235602696
[72347.211525] sd 0:0:0:0: [sda] tag#19 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[72347.211531] sd 0:0:0:0: [sda] tag#19 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[74147.255746] sd 0:0:0:0: [sda] tag#21 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[74147.255752] sd 0:0:0:0: [sda] tag#21 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[75947.299631] sd 0:0:0:0: [sda] tag#23 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[75947.299637] sd 0:0:0:0: [sda] tag#23 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[77747.345291] sd 0:0:0:0: [sda] tag#25 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[77747.345297] sd 0:0:0:0: [sda] tag#25 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[79547.389376] sd 0:0:0:0: [sda] tag#27 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[79547.389382] sd 0:0:0:0: [sda] tag#27 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00
[81347.432593] sd 0:0:0:0: [sda] tag#29 FAILED Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK
[81347.432598] sd 0:0:0:0: [sda] tag#29 CDB: ATA command pass through(16) 85 06 2c 00 00 00 00 00 00 00 00 00 00 00 e5 00我确实意识到需要更换驱动器,但我的目标只是在根分区上运行fsck。
发布于 2023-05-03 18:14:55
https://askubuntu.com/questions/1466430
复制相似问题