社区首页 >问答首页 >在AsrocJ5005-ITX上用nct6796d控制风扇。无法加载nct6775模块

在AsrocJ5005-ITX上用nct6796d控制风扇。无法加载nct6775模块
EN

Ask Ubuntu用户
提问于 2019-07-13 13:58:41
回答 1查看 1.4K关注 0票数 0

我试图控制风扇连接到我的Asrock J5005-ITX主板。我已经确定它包含了对此负责的Nuvoton NCT6796D芯片组。我被困在我想让sensors-detect发现它的地方了。从 linux驱动程序文件中,我了解到我需要加载nct6775模块。不幸的是,有些事情是不对的:

代码语言:javascript
复制
userName@Server:/$ sudo modprobe nct6775
userName@Server:/$ sudo sensors-detect
# sensors-detect revision 6284 (2015-05-31 14:00:33 +0200)
# Board: ASRock J5005-ITX
# Kernel: 4.18.0-25-generic x86_64
# Processor: Intel(R) Pentium(R) Silver J5005 CPU @ 1.50GHz (6/122/1)

This program will help you determine which kernel modules you need
to load to use lm_sensors most effectively. It is generally safe
and recommended to accept the default answers to all questions,
unless you know what you're doing.

Some south bridges, CPUs or memory controllers contain embedded sensors.
Do you want to scan for them? This is totally safe. (YES/no): y
Module cpuid loaded successfully.
Silicon Integrated Systems SIS5595...                       No
VIA VT82C686 Integrated Sensors...                          No
VIA VT8231 Integrated Sensors...                            No
AMD K8 thermal sensors...                                   No
AMD Family 10h thermal sensors...                           No
AMD Family 11h thermal sensors...                           No
AMD Family 12h and 14h thermal sensors...                   No
AMD Family 15h thermal sensors...                           No
AMD Family 16h thermal sensors...                           No
AMD Family 15h power sensors...                             No
AMD Family 16h power sensors...                             No
Intel digital thermal sensor...                             Success!
    (driver `coretemp')
Intel AMB FB-DIMM thermal sensor...                         No
Intel 5500/5520/X58 thermal sensor...                       No
VIA C7 thermal sensor...                                    No
VIA Nano thermal sensor...                                  No

Some Super I/O chips contain embedded sensors. We have to write to
standard I/O ports to probe them. This is usually safe.
Do you want to scan for Super I/O sensors? (YES/no): y
Probing for Super-I/O at 0x2e/0x2f
Trying family `National Semiconductor/ITE'...               No
Trying family `SMSC'...                                     No
Trying family `VIA/Winbond/Nuvoton/Fintek'...               Yes
Found unknown chip with ID 0xd423
    (logical device B has address 0x290, could be sensors)
Probing for Super-I/O at 0x4e/0x4f
Trying family `National Semiconductor/ITE'...               No
Trying family `SMSC'...                                     No
Trying family `VIA/Winbond/Nuvoton/Fintek'...               No
Trying family `ITE'...                                      No

Some systems (mainly servers) implement IPMI, a set of common interfaces
through which system health data may be retrieved, amongst other things.
We first try to get the information from SMBIOS. If we don't find it
there, we have to read from arbitrary I/O ports to probe for such
interfaces. This is normally safe. Do you want to scan for IPMI
interfaces? (YES/no): y
Probing for `IPMI BMC KCS' at 0xca0...                      No
Probing for `IPMI BMC SMIC' at 0xca8...                     No

Some hardware monitoring chips are accessible through the ISA I/O ports.
We have to write to arbitrary I/O ports to probe them. This is usually
safe though. Yes, you do have ISA I/O ports even if you do not have any
ISA slots! Do you want to scan the ISA I/O ports? (YES/no): y
Probing for `National Semiconductor LM78' at 0x290...       No
Probing for `National Semiconductor LM79' at 0x290...       No
Probing for `Winbond W83781D' at 0x290...                   No
Probing for `Winbond W83782D' at 0x290...                   No

Lastly, we can probe the I2C/SMBus adapters for connected hardware
monitoring devices. This is the most risky part, and while it works
reasonably well on most systems, it has been reported to cause trouble
on some systems.
Do you want to probe the I2C/SMBus adapters now? (YES/no): y
Found unknown SMBus adapter 8086:31d4 at 0000:00:1f.1.
Sorry, no supported PCI bus adapters found.

Next adapter: i915 gmbus dpb (i2c-0)
Do you want to scan it? (yes/NO/selectively): y

Next adapter: i915 gmbus dpc (i2c-1)
Do you want to scan it? (yes/NO/selectively): y

Next adapter: i915 gmbus misc (i2c-2)
Do you want to scan it? (yes/NO/selectively): y


Now follows a summary of the probes I have just done.
Just press ENTER to continue: y

Driver `coretemp':
  * Chip `Intel digital thermal sensor' (confidence: 9)

To load everything that is needed, add this to /etc/modules:
#----cut here----
# Chip drivers
coretemp
#----cut here----
If you have some drivers built into your kernel, the list above will
contain too many modules. Skip the appropriate ones!

Do you want to add these lines automatically to /etc/modules? (yes/NO)y
Successful!

Monitoring programs won't work until the needed modules are
loaded. You may want to run '/etc/init.d/kmod start'
to load them.

Unloading cpuid... OK

找不到模块。我做错了什么?

EN

回答 1

Ask Ubuntu用户

回答已采纳

发布于 2019-07-14 11:10:26

正如我所知道的,nct6775实际上是我想要的,所以我跳过了sensors-detect的步骤,手动将这个模块放到/etc/modules中。重新启动后,sensors命令显示风扇及其速度。我现在可以配置我的风扇曲线了。