我有一个raid10 btrfs卷。当我通过UUID挂载它时,挂载失败,我被引导到紧急模式。当我通过驱动器号(/dev/sdb/)挂载它时,服务器启动良好。这一切为什么要发生?
fstab:
/dev/sda2 /boot vfat defaults,noatime 0 2
/dev/sda3 / btrfs discard,ssd,compress=lzo,noatime 0 0
#e1ee5980-c54b-4b6e-82e2-3dbdcee1dd24 /mnt/store btrfs noatime 0 0
/dev/sdb /mnt/store btrfs noatime 0 0
gentooserver ~ # btrfs fi show
Label: none uuid: a782a62a-ffde-49b1-a680-0afeb9cdab0b
Total devices 1 FS bytes used 6.64GiB
devid 1 size 55.77GiB used 13.01GiB path /dev/sda3
Label: none uuid: e1ee5980-c54b-4b6e-82e2-3dbdcee1dd24
Total devices 10 FS bytes used 868.45GiB
devid 1 size 931.51GiB used 174.40GiB path /dev/sdb
devid 2 size 931.51GiB used 174.40GiB path /dev/sdc
devid 3 size 931.51GiB used 174.40GiB path /dev/sdd
devid 4 size 931.51GiB used 174.40GiB path /dev/sde
devid 5 size 931.51GiB used 174.40GiB path /dev/sdf
devid 6 size 931.51GiB used 174.40GiB path /dev/sdg
devid 7 size 931.51GiB used 174.40GiB path /dev/sdh
devid 8 size 931.51GiB used 174.40GiB path /dev/sdi
devid 9 size 931.51GiB used 174.40GiB path /dev/sdj
devid 10 size 931.51GiB used 174.40GiB path /dev/sdk关于卷的实际数据似乎很好,而且没有损坏。btrfs检查没有返回错误。systemctl状态没有返回有关错误的信息。
发布于 2018-04-21 02:45:01
你的语法不对。
它应该是:
UUID=e1ee5980-c54b-4b6e-82e2-3dbdcee1dd24 /mnt/store btrfs noatime 0 0发布于 2018-04-21 04:54:05
下面提到的语法错误
#e1ee5980-c54b-4b6e-82e2-3dbdcee1dd24 /mnt/store btrfs noatime 0 02.在命令开始时,需要添加"UUID =“。
https://unix.stackexchange.com/questions/439058
复制相似问题