录制Siebel VUgen脚本
EN

Stack Overflow用户
提问于 2013-09-11 13:56:23
回答 3查看 1.2K关注 0票数 1

我在录制VUGen脚本时遇到了两个问题。My配置:

  1. 负载转轮11.00
  2. Internet 8.0.6001.18702
  3. Windows XP Professional SP 3,i5-2500 K CPU @ 3.30 GHz,2.91 Gb内存

我使用Siebel - web协议,我们的应用程序使用https协议.

代码语言:javascript
复制
VUGen Recording options  are:
General-Script:
Generate think time greater than threshold = 3, checked
Track processes created as COM local servers
General – Protocols:
    Siebel –Web
General – Recording:
    HTML-based script
        Advanced- Script type = A script containing explicit URLs only
        Advanced – Non HTML generated elements =Do not record
Network
    Port Mapping
        Capture level = WinINET level data
HTTP Properties – Advanced
    Save snapshot resources locally checked
    Support charset = UTF-8 
HTTP Properties –Correlation
    Siebel correlation checked

第一个问题是:在我的主机上记录脚本时,会发生很多事件(仅从登录到大约800个)。我将它与我的虚拟机和我的联赛主机进行了比较。

这是我的主人的样本:

代码语言:javascript
复制
[Network Analyzer ( bf8:1714)] ------------------------------------------------------------------------------------------
[Network Analyzer ( bf8:1714)] Load Network Traffic Analyzers:
[Network Analyzer ( bf8:1714)]     Analyzer Module: Siebel_Web (value=)
[Network Analyzer ( bf8:1714)]     Analyzer Module: local_server (value=)
[Network Analyzer ( bf8:1714)] ------------------------------------------------------------------------------------------
[Network Analyzer ( bf8:1158)] Address lookup for wks03 = 172.31.86.25
[Network Analyzer ( bf8:1738)] Address lookup for wks03 = 172.31.86.25
[Network Analyzer ( bf8:1738)] Request Connection: Remote Server @ 192.168……..   (Service=)  (Sid=  1)  PROXIED!
[Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 77 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 1380 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 66 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 182 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 43 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 325 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 377 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 328 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 1746 bytes 
[WinInet Request  ( bf8: d08)] GET "https://bcvm168/fins_rus"
[Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 626 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 642 bytes 
[Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 2020 bytes 
[WinInet Request  ( bf8: d08)] GET "https://bcvm168/fins_rus/start.swe?SWECmd=Start&SWEHo=bcvm168"

这是我的虚拟机的示例:

代码语言:javascript
复制
[WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/files/main.css"
[WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/23016/scripts/login.js"
[WinInet Request  ( 86c: 8cc)] GET https://bcvm168/fins_rus/23016/scripts/swecommon_top.js

我不知道如何关掉这个网络分析器.

第二个问题是记录钻取操作的问题:

  • 我试图使用portmapping = wininet记录钻取,但失败了:在此之后记录了许多事件(大约3000次),之后IE选项卡恢复,没有其他任何记录。
  • 当我尝试使用端口映射套接字时,钻取不会失败,但是没有记录。请帮帮我。
EN

回答 3

Stack Overflow用户

发布于 2013-09-11 15:13:52

我认为你需要一位导师来帮助你在当地,因为你要求关闭的项目,是核心产品的能力记录。这意味着你已经被抛弃到这个角色中,很少或根本没有关于你正在使用的工具的培训。

如果上面的观察是正确的,并且要求你在一段时间内不接受工具、过程或导师的培训,这段时间可能长达一年(取决于你的基础技能),那么你应该意识到,这条道路的失败率几乎是100%,你的困境应归咎于你的管理层。

票数 0
EN

Stack Overflow用户

发布于 2013-11-11 14:46:52

嗯,一些实际经验给了我一种“作弊的方式”。当试图记录脚本时,通过在Windows不同进程之间切换来解决这个问题。例如,如果当我记录按钮单击时应用程序兑现,我点击它并最小化窗口与应用程序,在10-20秒后的步骤被记录。

票数 0
EN

Stack Overflow用户

发布于 2013-09-13 14:41:31

你能在你的机器上手动遍历流量吗?如果没有检查-所有可选相关的高交互性对象都加载了IE。C:\Windows\下载的程序文件

并在IE中添加URL作为受信任的站点。(互联网选项-安全选项卡)加-启用activeX控件和插件(互联网选项-安全选项卡-自定义级别)

更改LR- Portmapping =套接字级数据中的记录设置

希望能帮上忙!!