我正在使用LSI的MegaCLI命令转储我的2个RAID控制器的完整配置输出。我想解析文本文件,只打印出我感兴趣的行。例如:
"Adapter"
"Product Name"
"RAID Level Size State"
"Number Of Drives"
"Physical Disk"
"Raw Size"
"Link Speed"
"Media Type"
"Drive Temperature"但是,考虑到文件包含两个RAID控制器卡的配置数据(按降序排列),我如何才能最好地使用BASH来完成这个任务!下面是我正在处理的输出。
注意到:我应该提到,我计划很快安装另一个RAID控制器,所以理想情况下,我希望使用类似BASH的“read”内置的东西来读取文件。这样,脚本将自动捕获新安装的RAID控制器配置数据。
==============================================================================
Adapter: 0
Product Name: Supermicro SMC2208
Memory: 1024MB
BBU: Absent
Serial No:
==============================================================================
Number of DISK GROUPS: 1
DISK GROUP: 0
Number of Spans: 1
SPAN: 0
Span Reference: 0x00
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 54.947 GB
Sector Size : 512
Mirror Data : 54.947 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
PI type: No PI
Is VD Cached: No
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 0
Drive's postion: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 5
WWN: 5001517803d94502
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 55.899 GB [0x6fccf30 Sectors]
Non Coerced Size: 55.399 GB [0x6eccf30 Sectors]
Coerced Size: 54.947 GB [0x6de5000 Sectors]
Sector Size: 512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: 300i
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221103000000
Connected Port Number: 1(path0)
Inquiry Data: CVMP302300A6060AGN INTEL SSDSC2CT060A3 300i
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Solid State Device
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 1
Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: N/A
Device Id: 2
WWN: 5001517803d855bb
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 55.899 GB [0x6fccf30 Sectors]
Non Coerced Size: 55.399 GB [0x6eccf30 Sectors]
Coerced Size: 54.947 GB [0x6de5000 Sectors]
Sector Size: 512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: 300i
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221102000000
Connected Port Number: 0(path0)
Inquiry Data: CVMP3020013L060AGN INTEL SSDSC2CT060A3 300i
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Solid State Device
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
==============================================================================
Adapter: 1
Product Name: Supermicro SMC2208
Memory: 1024MB
BBU: Absent
Serial No:
==============================================================================
Number of DISK GROUPS: 1
DISK GROUP: 0
Number of Spans: 1
SPAN: 0
Span Reference: 0x00
Number of PDs: 2
Number of VDs: 1
Number of dedicated Hotspares: 0
Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 54.947 GB
Sector Size : 512
Mirror Data : 54.947 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAhead, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Bad Blocks Exist: No
PI type: No PI
Is VD Cached: No
Physical Disk Information:
Physical Disk: 0
Enclosure Device ID: 252
Slot Number: 0
Drive's postion: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 5
WWN: 5001517803d94502
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 55.899 GB [0x6fccf30 Sectors]
Non Coerced Size: 55.399 GB [0x6eccf30 Sectors]
Coerced Size: 54.947 GB [0x6de5000 Sectors]
Sector Size: 512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: 300i
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221103000000
Connected Port Number: 1(path0)
Inquiry Data: CVMP302300A6060AGN INTEL SSDSC2CT060A3 300i
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Solid State Device
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Physical Disk: 1
Enclosure Device ID: 252
Slot Number: 1
Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: N/A
Device Id: 2
WWN: 5001517803d855bb
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SATA
Raw Size: 55.899 GB [0x6fccf30 Sectors]
Non Coerced Size: 55.399 GB [0x6eccf30 Sectors]
Coerced Size: 54.947 GB [0x6de5000 Sectors]
Sector Size: 512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: 300i
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x4433221102000000
Connected Port Number: 0(path0)
Inquiry Data: CVMP3020013L060AGN INTEL SSDSC2CT060A3 300i
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Solid State Device
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00发布于 2013-07-27 14:07:43
当你说“只有巴什”的时候,你真的是认真的吗?bash本身是非常无力的;它实际上取决于拥有一组非内置命令来执行任何重要的操作。另外,你真的只是想要选择的行,还是想要重新格式化信息呢?
如果您只想要行(可能还有一些标题信息),并且有可用的egrep,那么这很简单:
MegaCLI -whateveroptions | egrep '^(Adapter|Product Name|RAID Level Size State|Number Of Drives|Physical Disk|Raw Size|Link Speed|Media Type|Drive Temperature):`如果您真的需要100%纯bash,可以使用read、case和echo来完成。
MegaCLI -whateveroptions | while read line; do
case "$line" in
Adapter:* | \
Product Name:* | \
RAID Level Size State:* | \
Number Of Drives:* | \
Physical Disk:* | \
Raw Size:* | \
Link Speed:* | \
Media Type:* | \
Drive Temperature:* )
echo "$line" ;;
esac
done发布于 2016-10-28 23:21:43
如果您对解析这些内容感到厌烦,我会考虑使用更新的LSI控制器和StorCLI64二进制文件。StorCLI有点类似于MegaCLI,但允许您将“J”附加到每个命令中,以便以JSON返回响应。
https://stackoverflow.com/questions/17894895