我试图直接实例化JMS资源,而不将JNDI用于远程HORNETQ。
我正在Eclipse中运行我的测试代码。设置我的类路径以使用HornetQ 2.2.5库。
目标HornetQ是2.1.2版本。最后,我认为它们应该向后兼容,也许我错了?
好的,我已经阅读了在线文档,并学习了不使用JNDI连接到远程JMS服务器的示例。我继续得到下面的例外。我不知道我错过了什么,但我相信我的一切都是正确的。有人能指出我在这里缺少什么吗?提前谢谢。
JMSException:未能创建会话工厂
hornetq-figation.xml上的连接器是:
<connector name="netty">
<factory-class>org.hornetq.core.remoting.impl.netty.NettyConnectorFactory</factory-class>
<param key="host" value="${10.100.111.222}"/>
<param key="port" value="${hornetq.remoting.netty.port:5445}"/>
</connector>接受者是:
<acceptor name="netty">
<factory-class>org.hornetq.core.remoting.impl.netty.NettyAcceptorFactory</factory-class>
<param key="host" value="${10.100.111.222}"/>
<param key="port" value="${hornetq.remoting.netty.port:5445}"/>
</acceptor>我的测试代码是: Connection = null;
try
{
Queue queue = HornetQJMSClient.createQueue("TESTQ");
Map<String, Object> connectionParams = new HashMap<String, Object>();
connectionParams.put(TransportConstants.PORT_PROP_NAME, 5445);
connectionParams.put(TransportConstants.HOST_PROP_NAME, "10.100.111.222");
TransportConfiguration transportConfiguration = new TransportConfiguration(NettyConnectorFactory.class.getName(),
connectionParams);
ConnectionFactory factory = (ConnectionFactory) HornetQJMSClient.createConnectionFactoryWithoutHA(JMSFactoryType.CF, transportConfiguration);
System.out.println("debug: " + factory.getClass());
connection = factory.createConnection();
Session session = connection.createSession(false, Session.AUTO_ACKNOWLEDGE);
MessageProducer producer = session.createProducer(queue);
TextMessage message = session.createTextMessage("This is a test message");
System.out.println("Sent message: " + message.getText());
producer.send(message);
}
finally
{
if (connection != null)
{
try {
connection.close();
} catch (JMSException e) {
// TODO Auto-generated catch block
e.printStackTrace();
}
}
}我得到以下异常
SEVERE: Failed to create netty connection
java.net.SocketTimeoutException: connect timed out
at java.net.PlainSocketImpl.socketConnect(Native Method)
at java.net.PlainSocketImpl.doConnect(Unknown Source)
at java.net.PlainSocketImpl.connectToAddress(Unknown Source)
at java.net.PlainSocketImpl.connect(Unknown Source)
at java.net.SocksSocketImpl.connect(Unknown Source)
at java.net.Socket.connect(Unknown Source)
at org.jboss.netty.channel.socket.oio.OioClientSocketPipelineSink.connect(OioClientSocketPipelineSink.java:114)
at org.jboss.netty.channel.socket.oio.OioClientSocketPipelineSink.eventSunk(OioClientSocketPipelineSink.java:74)
at org.jboss.netty.channel.Channels.connect(Channels.java:541)
at org.jboss.netty.channel.AbstractChannel.connect(AbstractChannel.java:218)
at org.jboss.netty.bootstrap.ClientBootstrap.connect(ClientBootstrap.java:227)
at org.jboss.netty.bootstrap.ClientBootstrap.connect(ClientBootstrap.java:188)
at org.hornetq.core.remoting.impl.netty.NettyConnector.createConnection(NettyConnector.java:450)
at org.hornetq.core.client.impl.ClientSessionFactoryImpl.getConnection(ClientSessionFactoryImpl.java:1016)
at org.hornetq.core.client.impl.ClientSessionFactoryImpl.getConnectionWithRetry(ClientSessionFactoryImpl.java:897)
at org.hornetq.core.client.impl.ClientSessionFactoryImpl.connect(ClientSessionFactoryImpl.java:212)
at org.hornetq.core.client.impl.ServerLocatorImpl.createSessionFactory(ServerLocatorImpl.java:602)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnectionInternal(HornetQConnectionFactory.java:611)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnection(HornetQConnectionFactory.java:121)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnection(HornetQConnectionFactory.java:116)
at com.ws.proto.ManualJMS.main(ManualJMS.java:39)
Oct 19, 2011 1:18:50 PM org.hornetq.core.logging.impl.JULLogDelegate warn
WARNING: Tried 1 times to connect. Now giving up on reconnecting it.
Exception in thread "main" javax.jms.JMSException: Failed to create session factory
at org.hornetq.jms.client.HornetQConnectionFactory.createConnectionInternal(HornetQConnectionFactory.java:615)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnection(HornetQConnectionFactory.java:121)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnection(HornetQConnectionFactory.java:116)
at com.ws.proto.ManualJMS.main(ManualJMS.java:39)
Caused by: HornetQException[errorCode=2 message=Cannot connect to server(s). Tried with all available servers.]
at org.hornetq.core.client.impl.ServerLocatorImpl.createSessionFactory(ServerLocatorImpl.java:619)
at org.hornetq.jms.client.HornetQConnectionFactory.createConnectionInternal(HornetQConnectionFactory.java:611)
... 3 more发布于 2011-10-19 21:11:52
关于兼容性:我们直到2.2.5+才有客户端兼容性。如果在2.2.2上试用client,在2.2.5使用服务器,可能会出现版本不匹配的异常。
我们的目标是始终与2.2.5+兼容
您的配置中有一个错误:
<connector name="netty">
<factory-class>org.hornetq.core.remoting.impl.netty.NettyConnectorFactory</factory-class>
<param key="host" value="10.100.111.222"/>
<param key="port" value="${hornetq.remoting.netty.port:5445}"/>
</connector>我们对属性和默认值使用语法。例如,您可以定义变量MY_IP,并将其用作:
${MY_IP:10.100.111.222}
如果MY_IP为null,则将得到10.100.111.222
但是"${10.100.111.222}“并不意味着什么。
https://stackoverflow.com/questions/7827919
复制相似问题