我在使用默认设置的标尺运行基准测试时出现以下错误。
这是一个独立的设置。
root@db3sample./ ~# /benchmark-run-all.sh配置/benchmark-Sample.properties
<17:26:41>无法设置基准驱动程序(将关闭并退出)。类org.apache.ignite.IgniteCheckedException:无法启动管理器: GridManagerAdapter enabled=true,name=org.apache.ignite.internal.managers.discovery.GridDiscoveryManager在org.apache.ignite.internal.IgniteKernal.startManager(IgniteKernal.java:1922)在org.apache.ignite.internal.IgniteKernal.start(IgniteKernal.java:1235)在org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance.start0(IgnitionEx.java:1787)在org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance.start(IgnitionEx.java:1711)在org.apache.ignite.internal.IgnitionEx.start0(IgnitionEx.java:1141)在org.apache.ignite.internal.IgnitionEx.start在org.apache.ignite.IgniteSpring.start(IgniteSpring.java:65) at org.apache.ignite.yardstick.IgniteNode.start(IgniteNode.java:220) at org.apache.ignite.yardstick.IgniteAbstractBenchmark.setUp(IgniteAbstractBenchmark.java:64) at org.apache.ignite.yardstick.cache.IgniteCacheAbstractBenchmark.setUp(IgniteCacheAbstractBenchmark.java:107) at org.yardstickframework.BenchmarkDriverStartUp.main(BenchmarkDriverStartUp.java:130)引起的(IgnitionEx.java:639):类org.apache.ignite.IgniteCheckedException:无法启动SPI: TcpDiscoverySpi [addrRslvr=null,sockTimeout=5000,ackTimeout=5000,marsh=JdkMarshaller clsFilter=org.apache.ignite.marshaller.MarshallerUtils$1@1eff3cfb,reconCnt=10,reconDelay=2000,maxAckTimeout=600000,soLinger=5,forceSrvMode=false,clientReconnectDisabled=false,internalLsnr=null,skipAddrsRandomization=false] at org.apache.ignite.internal.managers.GridManagerAdapter.startSpi(GridManagerAdapter.java:280) at org.apache.ignite.internal.managers.discovery.GridDiscoveryManager.start(GridDiscoveryManager.java:985) at org.apache.ignite.internal.IgniteKernal.startManager(IgniteKernal.java:1917) ... 10更多原因: class org.apache.ignite.spi.IgniteSpiException:无法联接节点(不兼容数据区域配置region=DEFAULT,rmtNodeId=4011d970-ae2d-4116-bb85-4311195c88a8,,locNodeId=8c2b6d02-01b3-4c22-8ad2-67c0c5f9ec4e,isPersistenceEnabled=trueorg.apache.ignite.spi.discovery.tcp.TcpDiscoverySpi.checkFailedError(TcpDiscoverySpi.java:2047) at org.apache.ignite.spi.discovery.tcp.ServerImpl.joinTopology(ServerImpl.java:1174) at org.apache.ignite.spi.discovery.tcp.ServerImpl.spiStart(ServerImpl.java:445) at org.apache.ignite.spi.discovery.tcp.TcpDiscoverySpi.spiStart(TcpDiscoverySpi.java:2149) at org.apache.ignite.internal.managers.GridManagerAdapter.startSpi(GridManagerAdapter.java:277的isPersistenceEnabled=false)
发布于 2021-10-27 17:49:40
(不兼容的数据区域配置协议、locNodeId=8c2b6d02-01b3-4c22-8ad2-67c0c5f9ec4e,isPersistenceEnabled=true、 isPersistenceEnabled=false)位于
您的节点具有不同的持久性配置,因此它们不会根据上面的错误相互联接。
https://stackoverflow.com/questions/69743088
复制相似问题