我将/etc/ceilometer/pipeline.yaml文件中的拉取间隔从600改为60,无法使服务使用新值。我在openstack-status命令中重新启动了所有与ceilometer相关的东西,但这不起作用。有人能告诉我怎么做才是正确的吗?
我在Ubuntu 14.04 LTS上使用Openstack Liberty
root@OS1:~# openstack service list
+----------------------------------+------------+---------------+
| ID | Name | Type |
+----------------------------------+------------+---------------+
| 056fcccaad5c4991a8a0da199ed1d737 | cinderv2 | volumev2 |
| 483a0cd1ba79430690a8960ae3d40222 | glance | image |
| 5c704fc9253e4c15895589eb19fab2ac | keystone | identity |
| 92bfcfb417314e80a43e6e7d4d21f99b | nova | compute |
| a7a3809d73674d3da3fbe8030b47055a | horizon | dashboard |
| c21b5e3c9d68417cb11df60d72f9bb58 | heat | orchestration |
| c7030edb082346328a715b00098b974a | neutron | network |
| d331f5360e2b4d3a854e7f47107a9421 | ec2 | ec2 |
| f0a22f827bed43dbbc43822abfc3e3e0 | ceilometer | metering |
+----------------------------------+------------+---------------+
root@OS11:~# openstack-status
.
.
.
== Ceilometer services ==
ceilometer-api: active
ceilometer-agent-central: active
ceilometer-agent-compute: inactive (disabled on boot)
ceilometer-collector: active
ceilometer-alarm-notifier: active
ceilometer-alarm-evaluator: active
ceilometer-agent-notification:active
.
.
.发布于 2016-10-09 12:30:29
由于ceilometer-agent-compute service已关闭,您只需在修改配置文件的节点上重启ceilometer-agent-central服务即可。
sudo service ceilometer-agent-central restart您可能希望在修改管道后自动重新加载管道,为此,您可以为pipeline_polling_interval设置refresh_pipeline_cfg=True和适当的时间,如/etc/ceilometer/ceilometer.conf中的120秒。
注意,启用自动重新加载时要小心,只有在确定内容正确后才保存管道配置文件(否则可能会丢失1个轮询周期数据)
发布于 2017-02-02 07:59:06
您需要重新启动ceilometer-agent-notification服务,因为此服务负责将数据转换为ceilometer数据库中的样本。
因此,systemctl restart ceilometer-agent-notification.service将有助于重启其他服务。
https://stackoverflow.com/questions/39775986
复制相似问题