我使用STM3240G-EVAL板从ADC读入值。我使用下面的打印功能将ADC的值打印到我板上的LCD上。我将温度传感器物理连接到评估板上的3.3V、ADC3和GND。返回的值太大。ADC分辨率应为12位,因此4096应为ADC_GetConversionValue函数输出的最大值。我正在接收室温下的5000+值!有没有人能直觉地知道为什么ADC值会变大?
////// stm324xg_eval.c
// to configure the ADC
void STM_EVAL_TEMPInit(Temp_TypeDef Temp)
{
RCC_PCLK2Config(RCC_HCLK_Div8);
RCC_APB2PeriphClockCmd(RCC_APB2Periph_ADC3, ENABLE);
/* Enable the GPIO_TEMP Clock */
RCC_AHB1PeriphClockCmd(GPIO_TEMP_CLK[Temp], ENABLE);
/* Configure the GPIO_TEMP pin */
GPIO_InitTypeDef GPIO_InitStructure;
GPIO_InitStructure.GPIO_Pin = GPIO_TEMP_PIN[Temp];
GPIO_InitStructure.GPIO_Mode = GPIO_Mode_AN;
GPIO_InitStructure.GPIO_PuPd = GPIO_PuPd_NOPULL;
GPIO_InitStructure.GPIO_Speed = GPIO_Speed_50MHz;
GPIO_Init(GPIO_TEMP_PORT[Temp], &GPIO_InitStructure);
/* Enable ADC3 Clock */
ADC_InitTypeDef ADC_InitStructure;
ADC_CommonInitTypeDef ADC_CommonInitStructure;
ADC_CommonInitStructure.ADC_Mode = ADC_Mode_Independent;
ADC_CommonInitStructure.ADC_Prescaler = ADC_Prescaler_Div4;
ADC_CommonInitStructure.ADC_DMAAccessMode = ADC_DMAAccessMode_Disabled;
ADC_CommonInitStructure.ADC_TwoSamplingDelay = 0;
ADC_CommonInit(&ADC_CommonInitStructure);
ADC_InitStructure.ADC_ContinuousConvMode = DISABLE;
ADC_InitStructure.ADC_Resolution = ADC_Resolution_12b;
ADC_InitStructure.ADC_ScanConvMode = DISABLE;
ADC_InitStructure.ADC_ExternalTrigConvEdge = ADC_ExternalTrigConvEdge_None;
ADC_InitStructure.ADC_DataAlign = ADC_DataAlign_Right;
ADC_Init(ADC3, &ADC_InitStructure);
ADC_RegularChannelConfig(ADC3, ADC_Channel_4, 1, ADC_SampleTime_144Cycles);
ADC_Cmd(ADC3, ENABLE);
}
////// main.cpp
// to print to lcd
ADC_SoftwareStartConv(ADC3);
temp_value = ADC_GetConversionValue(ADC3);
uint8_t mymsg[20];
sprintf((char *)mymsg, "ADC = %d",(int)temp_value);
LCD_DisplayStringLine(Line6, mymsg);
////// stm32f4xx_adc.c
// ADC_GetConversionValue function
/**
* @brief Returns the last ADCx conversion result data for regular channel.
* @param ADCx: where x can be 1, 2 or 3 to select the ADC peripheral.
* @retval The Data conversion value.
*/
uint16_t ADC_GetConversionValue(ADC_TypeDef* ADCx)
{
/* Check the parameters */
assert_param(IS_ADC_ALL_PERIPH(ADCx));
/* Return the selected ADC conversion value */
return (uint16_t) ADCx->DR;
}发布于 2014-08-05 23:42:36
我缺少一个ADC配置;
ADC_InitStructure.ADC_NbrOfConversion = 1;确保在使用ADC时使用了所有配置,并且没有遗漏任何配置。在包含这个之后,我能够使用万用表获得与传感器读取的ADC值相同的电压。
新增说明:
这是因为您已经将以下结构定义为本地结构:
ADC_InitTypeDef ADC_InitStructure;
ADC_CommonInitTypeDef ADC_CommonInitStructure;并且局部变量具有不可靠(随机)初始值,因此当其已被写入相应的寄存器中时,其可能导致例如变为不适当的数字,从而造成这样的问题。
发布于 2014-07-18 05:37:52
您必须等待转换完成:
ADC_SoftwareStartConv(ADC3);
while( ADC_GetFlagStatus( ADC3, ADC_FLAG_EOC ) == RESET )
{
// do nothing (or something useful perhaps)
}
temp_value = ADC_GetConversionValue(ADC3);发布于 2014-07-17 10:09:29
您是否测量了温度传感器上的电压、ACD输入端上的电压和设备上的VCC电压?最好在获取此5000+输出时包含它们的运行时值。
您是否尝试将已知的提前电压(例如3.3V)馈送到相同的ADC输入,并比较测量/获得的值?因为你测量的电压和4+V一样,取5000+。
至于代码,最好屏蔽返回值,以便只考虑12位:
return (uint16_t) ((ADCx->DR) & 0xFFF)
https://stackoverflow.com/questions/24792904
复制相似问题